ERBE ICC 350
The top-of-the-line ERBOTOM ICC 350 heads ERBE’s family of units for HF surgery. They’ve given it one-of-a-kind functionality for all-around use, with the features and abilities developed in close teamwork with leading surgeons from many different medical disciplines.
The ICC 350 has received worldwide attention and recognition; it is a step forward from conventional surgical methods and opens the way for new ones.
General surgery
Dermatology
Endoscopy
Gastroenterology
Vascular Surgery
Genecology
Neurosurgery
Plastic Surgery
Oral surgery
ERBE Erbotom ICC 350 Specifications
Dimensions
Dimensions (W x H x D): 410 × 152 × 368 mm
Weight: 10.0 kg
Electrical
Rated power voltage: 240V/230V/115V/110V/100V± 10%
Rated power frequency: 50/60 Hz
Power current: 4.0 A at 230 – 240 V/8.0 A at 100-115 V
Power consumption in Standby mode: 25 watts
Power consumption at max. HF power: 620 watts 920 VA
Current consumption in Standby mode: 150 mA at 230 – 240V/300 mA at 100-115 V
Potential equalization terminal: Yes
Power fuses: 2 slow burn, 4 A at 230 – 240 V/8 A at 100-115 V
Cutting
HF power adjustment: With up/down increment keys
Form of HF voltage: Sine-shaped
Nominal frequency of HF voltage: 330 kHz
Cutting quality: 4 coagulation effects, selectable by key
Constancy of the coagulation effects: Automatically regulated
Support for initial incision and cutting: PPS, PowerPeakSystem
Monopolar AUTO CUT: With automatic voltage control
Monopolar HIGH CUT: with automatic arc control
Nominal HF output: 300 watts at 500 ohms
Peak HF power with PPS: 400 watts at 500 ohms
Monopolar ENDO CUT: 200 watts at max 200 ohms
BIPOLAR AUTO CUT: With automatic voltage control
Nominal HF output: 100 watts at 500 ohms
Coagulation
HF power adjustment: With up/down increment keys
Monopolar SOFT COAG
Form of HF current: Sine-shaped
Nominal frequency of HF voltage: 300 kHz
Nominal HF output: 120 watts at 125 ohms
End of coagulation: with Pedal or AUTO STOP
Monopolar FORCED COAG
Form of HF current: Pulse-modulated
Nominal frequency of HF voltage: 1 MHz
Nominal HF output: 120 atts at 350 ohms
Monopolar SPRAY COAG
Form of HF current: Pulse-modulated
Nominal frequency of HF voltage: 1 MHz
Nominal HF output: 120 watts at 500 ohms
Bipolar COAG
Form of HF current: Sine-shaped
Nominal frequency of HF voltage: 330 kHz
Nominal HF output: 120 watts at 125 ohms
Start of coagulation: By foot pedal or AUTO START
End of coagulation: By foot pedal or AUTO STOP
Safety Precautions
Safety class: I, corresponds to DIN IEC 601-1
Type: CF, corresponds to DIN IEC 601-1
Software check of LF leakage current, Icritical: 0.05mA (only with capacitive grounding)
Software check of HF leakage current, Icritical: 150 mA/300MA
NESSY: Neutral electrode Safety System
Neutral electrode switching: Switch-selectable capacitively grounded or with floating power.
Self-Check: Includes all safety-related subassemblies.
Environmental Conditions for Storage
Temperature -40°C to + 70°C
Air humidity, relative 30% to 95%
Environmental Conditions for Operating
Temperature +10°C to + 40°C
Air humidity, relative 30% to 75%, noncondensing